Magnehelic®Differential Pressure Gage1/8 FEMALE NPTHIGH PRESSURECONNECTION1-3/4(44.45)1/2(12.70)1/8 FEMALENPT LOWPRESSURE CONNECTION11/16(17.46)17/32(13.49)ø4-3/4 (120.65) PANEL CUTOUTø5(127)ø4-47/64(120.27)3/16(4.76)2-17/32(64.29)15/32(11.91)ø4-1/2(114.3)1-1/4(31.75)ø5-1/2(139.70) MOUNTING RINGRUBBER PRESSURE RELIEF PLUG WILL UNSEAT ITSELFWHEN GAGE ISOVERPRESSURIZED(3) 6-32 X 3/16 (4.76) DEEP HOLESEQUALLY SPACED ON A Ø4-1/8(104.78) BOLT CIRCLE FORPANEL MOUNTING1/8 FEMALE NPTHIGH PRESSURE CONNECTION1-3/4(44.45)1/2(12.70)1/8 FEMALE NPTLOW PRESSURECONNECTION11/16(17.46)15/32(11.91)1-11/16(42.86)Ø4-1/2(114.3)1-1/4(31.75)17/32(13.49).025 (.64) SPACE CREATED BY 3SPACER PADS WHEN SURFACE MOUNTED. DO NOT OBSTRUCT. PROVIDES PATH FOR RELIEF OF OVERPRESSURE. 1/8 FEMALENPT HIGH PRESSURECONNECTION1/8 FEMALENPT LOW PRESSURECONNECTION7/16(11.11)Ø4-3/4(120.65)Bulletin A-27SPECIFICATIONSService: Air and non-combustible, compatible gases. (NaturalGas option available.)Wetted Materials:Consult factory. Housing: Die cast aluminum case and bezel, with acryliccover. (MP model has polycarbonate cover).Accuracy: 2% of full scale (±3% on -0, -100PA, -125PA, -10MM and ±4% on -00, -60PA, -6MM), throughout range at70°F (21.1°C); High accuracy version: ±1% on full scale(±1.5% on -0, -100PA, -125PA, -10MM and ±2% on -00, -60PA, -6MM).Pressure Limits: -20˝ Hg to 15 psig.† (-0.677 bar to 1.034bar); MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52bar).Enclosure Rating:IP67.Overpressure: Relief plug opens at approximately 25 psig(1.72 bar), standard gages only. The blowout plug is not usedon models above 180 inches of water pressure, medium orhigh pressure models, or on gages which require an elastomerother than silicone for the diaphragm.Temperature Limits: 20 to 140°F (-6.67 to 60°C). *Lowtemperature models available as special option.Size: 4˝ (101.6 mm) diameter dial face.Mounting Orientation: Diaphragm in vertical position.Consult factory for other position orientations.Process Connections: 1/8˝ female NPT duplicate high andlow pressure taps - one pair side and one pair back.Weight: 1 lb 2 oz (510 g), MP & HP 2 lb 2 oz (963 g).Agency Approvals:RoHS.†For applications with high cycle rate within gage total pressure rating,nexthigher rating is recommended. See Medium and High pressureoptions.Note:May be used with hydrogen when ordering Buna-N diaphragm.Pressure must be less than 35 psi.STANDARD GAGE ACCESSORIES: Two 1/8˝ NPT plugs forduplicate pressure taps, two 1/8˝ pipe thread to rubber tubingadapters and three flush mounting adapters with screws.MP AND HP GAGE ACCESSORIES:Mounting ring and snapring retainer substituted for 3 adaptors, 1/4” compression fittingsreplace 1/8” pipe thread to rubber tubing adaptors.OVERPRESSURE PROTECTION:Standard Magnehelic®Differential Pressure Gagesare rated for a maximumpressure of 15 psig and should not be used where that limitcould be exceeded. Models employ a rubber plug on the rearwhich functions as a relief valve by unseating and venting thegage interior when over pressure reaches approximately 25psig (excludes MP and HP models). To provide a free path forpressure relief, there are four spacer pads which maintain .023˝clearance when gage is surface mounted. Do not obstruct thegap created by these pads. *The blowout plug is not used on models above 180 inches of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm.DWYER INSTRUMENTS, INC.P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.Phone: 219/879-8000 www.dwyer-inst.comFax: 219/872-9057 e-mail: info@dwyer-inst.comPIPE MOUNTINGTo mount gage on 1-1/4” - 2” pipe, order optional A-610 pipemounting kit.TO zERO GAGE AFTER INSTALLATIONSet the indicating pointer exactly on the zero mark, using theexternal zero adjust screw on the cover at the bottom. Note thatthe zero check or adjustment can only be made with the highand low pressure taps both open to atmosphere. OPERATIONPositive Pressure: Connect tubing from source of pressure toeither of the two high pressure ports. Plug the port not used.Vent one or both low pressure ports to atmosphere.Negative Pressure:Connect tubing from source of vacuum ornegative pressure to either of the two low pressure ports. Plugthe port not used. Vent one or both high pressure ports toatmosphere. Differential Pressure:Connect tubing from the greater of twopressure sources to either high pressure port and the lower toeither low pressure port. Plug both unused ports.When one side of the gage is vented in dirty, dusty atmosphere,we suggest an A-331 Filter Vent Plug be installed in the openport to keep inside of gage clean.A.For portable use of temporary installation use 1/8” pipethread to rubber tubing adapter and connect to source ofpressure with flexible rubber or vinyl tubing.B.For permanent installation, 1/4” O.D., or larger, copper oraluminum tubing is recommended. MAINTENANCENo lubrication or periodic servicing is required. Keep caseexterior and cover clean. Occasionally disconnect pressurelines to vent both sides of gage to atmosphere and re-zero.Optional vent valves should be used in permanent installations.The Series 2000 is not field serviceable and should be returnedif repair is needed (field repair should not be attempted and mayvoid warranty). Be sure to include a brief description of theproblem plus any relevant application notes. Contact customerservice to receive a return goods authorization number beforeshipping.WARNINGAttempted field repair may void your warranty. Recalibration orrepair by the user is not recommended.TROUBLE SHOOTING TIPSGage won’t indicate or is sluggish.1. Duplicate pressure port not plugged.2. Diaphragm ruptured due to overpressure.3. Fittings or sensing lines blocked, pinched, or leaking.4. Cover loose or “O”ring damaged, missing.5. Pressure sensor, (static tips, Pitot tube, etc.) improperly located.6. Ambient temperature too low. For operation below 20°F (-7°C), order gage with low temperature, (LT) option.INSTALLATIONSelect a location free from excessive vibration and where theambient temperature will not exceed 140°F (60°C). Also, avoiddirect sunlight which accelerates discoloration of the clearplastic cover. Sensing lines may be run any necessary distance.Long tubing lengths will not affect accuracy but will increaseresponse time slightly. Do not restrict lines. If pulsatingpressures or vibration cause excessive pointer oscillation,consult the factory for ways to provide additional damping. All standard Magnehelic®Differential Pressure Gages arecalibrated with the diaphragm vertical and should be used inthat position for maximum accuracy. If gages are to be used inother than vertical position, this should be specified on theorder. Many higher range gages will perform within tolerance inother positions with only rezeroing. Low range models of 0.5”w.c. plus 0.25” w.c. and metric equivalents must be used in thevertical position only.SURFACE MOUNTINGLocate mounting holes, 120° apart on a 4-1/8” dia. circle. UseNo. 6-32 machine screws of appropriate length.FLUSH MOUNTINGProvide a 4-9/16” dia. (116 mm) opening in panel. Provide a 4-3/4” dia. (120 mm) opening for MP and HP models. Insert gageand secure in place with No. 6-32 machine screws ofappropriate length, with adapters, firmly secured in place. FOR -SS BEzEL INSTALLATIONProvide a 4-9/16˝ opening in panel. Insert gage and secure withsupplied mounting hardware.DWYER INSTRUMENTS, INC.P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.Phone: 219/879-8000 www.dwyer-inst.comFax: 219/872-9057 e-mail: info@dwyer-inst.comMagnehelic®Differential Pressure GageINSTRUCCIONES Y LISTA DE PARTES1/8 FEMALE NPTHIGH PRESSURECONNECTION1-3/4(44.45)1/2(12.70)1/8 FEMALENPT LOWPRESSURE CONNECTION11/16(17.46)17/32(13.49)ø4-3/4 (120.65) PANEL CUTOUTø5(127)ø4-47/64(120.27)3/16(4.76)2-17/32(64.29)15/32(11.91)ø4-1/2(114.3)1-1/4(31.75)ø5-1/2(139.70) MOUNTING RINGRUBBER PRESSURE RELIEF PLUG WILL UNSEAT ITSELFWHEN GAGE ISOVERPRESSURIZED(3) 6-32 X 3/16 (4.76) DEEP HOLESEQUALLY SPACED ON A Ø4-1/8(104.78) BOLT CIRCLE FORPANEL MOUNTING1/8 FEMALE NPTHIGH PRESSURE CONNECTION1-3/4(44.45)1/2(12.70)1/8 FEMALE NPTLOW PRESSURECONNECTION11/16(17.46)15/32(11.91)1-11/16(42.86)Ø4-1/2(114.3)1-1/4(31.75)17/32(13.49).025 (.64) SPACE CREATED BY 3SPACER PADS WHEN SURFACE MOUNTED. DO NOT OBSTRUCT. PROVIDES PATH FOR RELIEF OF OVERPRESSURE. 1/8 FEMALENPT HIGH PRESSURECONNECTION1/8 FEMALENPT LOW PRESSURECONNECTION7/16(11.11)Ø4-3/4(120.65)Bulletin A-27(El tapón de goma no es usado en los modelos sobre 180 pulgadas de presión de agua, modelos de presión media o alta, o en instrumentos que requierenun elastizado en cualquier otro material que no sea silicona para el diafragma.) Accesorios: Tapones 1/8” NPT para las conexionesduplicadas, dos adaptadores de rosca 1/8” NPT a tubo degoma; y tres adaptadores para montaje al ras y tornillos.Accesorios para Los Modelos MP y HP:El anillo de montajey el retensor del anillo de presión son substituidos por 3adaptadores, accesorios de compresión de 1/4” remplazan alos adaptadores de rosca 1/8” a tubo de goma. Protección Para Sobrepresión: Los ManómetrosDiferenciales Magnehelic Estándar están clasificados para unapresión máxima de 15 psi y no se deberían de usar donde ellímite puede excederse. Los modelos emplean un tapón degoma en el trasero que funciona como una válvula de aliviodesmontándose y ventilando el interior del instrumento cuandola sobrepresión alcanza aproximadamente 25 psig. (Losmodelos MP y HP son excluidos) Para proveer un camino librepara el alivio de presión, el instrumento viene con rodilleras quemantienen un espacio de .023” cuando el instrumento esmontado en superficie. No bloque el espacio creado por estasrodilleras.DWYER INSTRUMENTS, INC.P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.Phone: 219/879-8000 www.dwyer-inst.comFax: 219/872-9057 e-mail: info@dwyer-inst.comDWYER INSTRUMENTS, INC.P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.Phone: 219/879-8000 www.dwyer-inst.comFax: 219/872-9057 e-mail: info@dwyer-inst.com©Copyright 2017 Dwyer Instruments, Inc. Printed in U.S.A. 6/17 FR# 440212-10 Rev. 6InstalacíonSeleccione un lugar libe de exceso de vibraciones, y donde latemperatura ambiente no supere los 60°C. Evite luz solardirecta, para evitar decoloración de la cubierta plástica. Lasconexiones de proceso pueden tener cualquier longitud sinafectar la exactitud, pero pueden extender el tiempo derespuesta del instrumento. Si hay pulsación de presión ovibración, consulte a fábrica sobre medios de amortiguación. Los MAGNEHELIC han sido calibrados con el diafragmavertical, y deben ser usados en esas condiciones. Para otrasposiciones, se debe especificar en la orden de provisión. Losde rango elevado pueden ser usados en diversas posiciones,pero se debe reajustar el cero. Los modelos de la serie 2000-00 y equivalentes métricos deben ser usados soloverticalmente.Montaje en SuperficiePerfore tres orificios separados 120° sobre una circunferenciade 105 mm de diám. y sostenga el instrumento con tres tornillos6-32 de long. apropiada.Montaje alineadoPerfore un circulo de 115 mm de diám. en el panel, y sostengael instrumento mediante los.Para instalar el bisel de acero inoxidableHaga una apertura de 4-9/16 pulgadas en el panel. Inserte elmedidor y asegure con los herrajes de montaje provistos.Montaje Sobre PipaPara montar el instrumento sobre pipas de 32 a 50 mm dediám., ordene el adaptador opcional A-610.Puesta a Cero Después de InstalarDeje las conexiones de presión abiertas a atmósfera y ajuste acero desde tornillo del panel frontal.OperacionPresión Positiva:Conecte la tubería desde la fuente depresión a cualquiera de las dos conexiones de alta presión(HIGH), bloqueando la no usada; Las conexiones de baja(LOW) presión pueden dejarse uno o los dos abiertos a laatmósfera.Presión Negativa: Repita el procedimiento anterior, conectadoen este caso las conexiones de baja presión (LOW). Deje lasotras conexiones abiertas.Presión diferencial:Conecte el tubo correspondiente a lapresión más positiva al cualquiera de los conectores de altapresión (HIGH) bloqueando el no usado, y la más baja presióno presión negativa (vacío) al conector de baja presión (LOW).Puede usarse cualquier conector de cada par, dejando siempreuno bloqueado. Si se deja una conexión abierta a la atmósfera,se recomienda el uso de un filtro tipo A-331 en el lugarcorrespondiente para mantener limpio el interior delinstrumento. Para uso portable, o instalación temporaria, usoadapta dores para rosca de tubo de 1/89 a tubo flexible, yconecte a proceso mediante una tubería de goma, oequivalente. Para instalación permanente, se recomienda eluso de tubo de cobre o aluminio de por lo menos 1/4“ de diám.exterior.No se requiere mantenimiento específico alguno, ni lubricación.Periódicamente, desconecte el instrumento, ventee la presiónacumulada, y reajuste el cero. Para instalaciones permanentes,se debe usar un juego de válvulas de montaje permanentepara el venteo.El instrumento de Serie 2000 no puede ser re parado en elcampo y debería de ser regresado si reparos son necesarios(Reparos en el campo no deben de ser intentados y puedencancelar la garantía.). Asegurarse de incluir una descripciónbreve del problema más cualquier notas pertinentes a laaplicación para devolución de productos antes de enviar elinstrumento.Cuidado! : La recalibración en campo puede invalidar lagarantía. No se recomienda la recalibracion por parte delusuario. En caso necesario envie el instrumento contransporte pago a:Localización De Fallas• El instrumento no indica, o es lento en reacción.1. Conexión duplicada abierta.2. Diafragma roto por sobrepresión.3. Tubería de conexión perforada, con pérdidas o pinchazos.4. Anillo de retención flojo, u “O “ ring dañado.5. Conexión a proceso indebida o inadecuada.6. Temperatura muy baja. Para este caso ordene tipos LT (baja temperatura).† Para aplicaciones con alto ciclo de velocidad dentro de la clasificación depresión total del instrumento, la próxima clasificación mas alta esrecomendada. Vea las opciones de media y alta presión.El instrumento puede ser usado con hidrogeno cuando se ordena condiafragma de Buna-N. La presion tiene que ser menos de 35 psi.ESPECIFICACIONESServicio: aire y gases no combustibles, gases compatibles.(ópcion disponible para uso con gas natural).Materiales Mojados:Consulte con la fábrica.Carcasa:Caja y anillo de retención de aluminio fundido apresión con tapadera de acrílico. (El modelo MP tiene latapadera de policarbonato.)Exactitud: ±2% de la escala completa (±3% en los márgenesde -0, -100PA, -125PA y -10MM y ±4 % en los márgenes de -00, -60PA y -6MM), en todo el margen a 21.1 °C (70 °F);Versión de alta precisión: ±1% de la escala completa (±1.5%en los márgenes de -0, -100PA, -125PA, -10MM y ±2% en losmárgenes de -00, -60PA, -6MM).Límite de Presión: -20 Hg. a 15 psig. † (-0.677 bar a 1,034bar); opción MP: 35 psig (2.41 bar), opción HP: 80 psig (5.52bar).Clasificación de gabinete:IP67.Sobrepresión: El tapón de alivio se abre aproximadamente alos 25 psig, modelos estandard únicamente. El tapón degoma no es usado en los modelos sobre 180 pulgadas depresión de agua, modelos de presión media o alta, o eninstrumentos que requieren un elastizado en cualquier otromaterial que no sea silicio para el diafragma.Límite de Temperatura: -6.67 a 60ºC. * Modelos de bajatemperatura disponibles como opción especial.Dimensiones: diám. 120,65 mm x 55,6 prof. Orientación de Montaje:El diafragma debe ser usado soloen posición vertical. Consulte con la fábrica para otrasorientaciones de posición.Conexiones: 1/8” NPT para alta y baja presión, duplicadas(atrás, a los lados).Peso:510 g, MP y HP 963 g.Aprobación de la agencia:RoHS.Next >