Automation Components, Inc.TEMPERATURE | TRANSMITTERS | HAZARDOUSPRODUCT SPECIFICATIONSTEMPERATURE | ## Call: 1-888-967-5224 | Web: www.workaci.com Transmitter Supply Voltage | Supply Current:Maximum Load Resistance:Output Signals:Calibrated Transmitter Accuracy | Linearity:Temperature Drift:Protection Level:Warm Up Time | Warm Up Drift:Operating | Storage Temperature Range:Operating Humidity Range:Calibrated Temperature Spans:Connections:Sensor Type | Sensor Curve | Sensing Points:Number Sensor Wires | Wire Colors:Nominal Sensor Output @ 0°C (32°F):Sensor Tolerance Class | Accuracy:Din Standard | Temperature Coecient:Sensor Stability:Response Time (63% Step Change):Lead Length | Conductor Size:Lead Wire Insulation | Wire Rating:Conductor Material:Enclosure Specications (Material, Operating Temperature, NEMA Ratings):Enclosure Explosion Proof Rating:Enclosure Dust-Ignition Proof Rating:Enclosure Raintight | Wet Locations Ratings:Enclosure UL | CSA Standards:Sensor Operating | Storage Temperature Ranges:Operating Humidity Range:Enclosure Hubs | Hub Size:Probe Material | Diameter | Sensor Threads:Thermowell Material | Bore Diameter:Thermowell Instrument Thread | Process Thread:Product Dimensions | Product Weight:Agency Approvals:+8.5 to 32 VDC (Reverse Polarity Protected) | 25 mA minimum250 Ohm Load (1-5 VDC): +13.5 to 32 VDC | 500 Ohm Load (2-10 VDC): +18.5 to 32 VDC (Terminal Voltage - 8.5 V) | 0.020 A Current: 4-20 mA (2-Wire; Loop Powered) | Voltage: 1-5 VDC or 2-10 VDC (3-Wires)Temp. Spans < 500ºF (260ºC): +/- 0.2% | Temp. Spans > 500ºF (260ºC): +/- 0.5% Temp. Spans < 100ºF (38ºC): +/- 0.04%/ºF | Temp. Spans > 100ºF (38ºC): +/- 0.02%Thermally Conductive, Low Moisture, Corrosion Resistant Epoxy / Plastic Cup10 Minutes | +/- 0.1% -40ºF to 185ºF (-40 to 85ºC)0 to 95%, non-condensing Minimum Temp. Span: 50ºF (28ºC) | Maximum Temp. Span: 500ºF (260ºC) 22 AWG (0.654 mm) Colored Leads; Polarity Sensitive | 22 to 15 AWG Wire NutsPlatinum RTD | PTC (Positive Temperature Coecient) | One Two | A/TT100/TTM100-EXPL: Brown/Brown | A/TT1K/TTM1K-EXPL: (Black/Black)A/TT100/TTM100-EXPL: 100 Ohms | A/TT1K/TTM1K-EXPL: 1000 Ohms +/- 0.06% Class A | (Tolerance Formula: +/- ºC = (0.15ºC + (0.002 * |t|)) where |t| is the absolute value of Temperature above or below 0ºC in ºC)DIN EN 60751 (IEC 751) | 3850 ppm / ºC+/- 0.03% after 1000 Hours @ 300ºC (572ºF)8 Seconds nominal14” (35.6 cm) or 24” (61 cm) | 22 AWG (0.65mm)Etched Teon (PTFE) Colored Leads | Mil Spec 16878/4 Type E)Silver Plated Copper“-D” Enclosure: Feraloy® Iron Alloy, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFG “-I or -INW” Enclosure: Feraloy® Iron Alloy, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFG“-R” Enclosure: Copper-Free Aluminum, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFGCL. I, Div. 1 & 2, Groups A, B, C, DCL. II, Div. 1, Groups E, F, GCL. II, Div. 2, Groups F, G | CL. III“-R” Series: UL 1203 | “-D”, “-I” or “-INW” Series: UL 886 | All Models: CSA C22.2 No. 30-40 to 200ºC (-40 to 392ºF) | -40 to 85ºC (-40 to 185ºF)0 to 95% RH, non-condensingTwo | 1/2” NPT Female Hubs 304 Stainless Steel | 0.250” (6.35mm) nominal | ½” NPT Threads304 Stainless Steel | 0.260” nominal½” NPS (National Pipe Straight) Female Thread | ½” NPT (National Pipe Tapered) Male ThreadSee table on back of Product Data sheetRoHS2, WEEENote: Transmitter’s calibrated at 71ºF (22ºC) nominal | Note: Temperature Drift is referenced to 71ºF nominal calibration temperatureDuctImmersionRoomHAZARDOUSRoom, Duct & Immersion TransmittersThe ACI Hazardous Transmitter Series features an encapsulated temperature transmitter mounted in an industrial connection head style enclosure. The epoxy coating provides excellent protection of the transmitter from moisture and corrosion when used in harsh environments and improved accuracy due to the thermal conductivity of the epoxy keeping the components at a more stable operating temperature. The sensors are manufactured using ACI’s double encapsulation process to eliminate the eects of moisture upon the sensors and to increase response times. For higher accuracies, ACI recommendst the use of the A/TTM Series transmitters which includes a secondary calibration process that removes most of the sensor error over the calibrated temperature span of your transmitter and includes a 3 or 5 Point NIST Certicate. The unit includes an O-Ring seal, ground screw, and weather resistant nish. The “INW” Immersion sensor without thermowell can be used with an existing thermowell or paired with one of our machined thermowells when higher ow rates, temperatures, pressure rating or corrosion resistance is required. This product should be installed by a trained professional with knowledge of local codes and regulations. Applications: Hazardous Atmospheres, Industrial Sensor Applications, Process Control, Exhaust Systems The ACI Hazardous Transmitter Series is covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.R = Room with 2” Stainless Steel Sensing TubeD. Conguration No Selection RequiredRRevision C0000002 | Rev 1.0Automation Components, Inc.TEMPERATURE | TRANSMITTERS | HAZARDOUSTEMPERATURE | ## Call: 1-888-967-5224 | Web: www.workaci.com TT100 = 100 | TTM100* = Matched 100 | TT1K = 1K | TTM1K* = Matched 100 A/HAZARDOUS ROOM ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)EXPL = Hazardous SensorE. Sensor Model No Selection RequiredMODEL #A/EXPLEXPLModel # Example:TT100 = 100 | TTM100* = Matched 100 | TT1K = 1K | TTM1K* = Matched 100 A/D = DuctHAZARDOUS DUCT ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)C. Conguration No Selection Required4” = Duct 4” | 8” = Duct 8” | 12” = Duct 12” | 18” = Duct 18” D. Duct Probe Length Select One (1)MODEL #A/DModel # Example:TT1KB.A/A.DC.8”D.1E.EXPLF.G.Specify Span in ºF or ºC (Best Accuracy in 100ºF Increments)F. Calibrated Span1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mA F. Analog Output Select One (1)1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mA E. Analog Output Select One (1)1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mA E. Analog Output Select One (1)TT100B.A/A.RC.2D.EXPLE.F.EXPL = Hazardous SensorF. Sensor Model No Selection RequiredEXPLTT100 = 100 | TTM100* = Matched 100 | TT1K = 1K | TTM1K* = Matched 100 A/I = Immersion with Welded Thermowell | INW = Immersion without Welded ThermowellHAZARDOUS IMMERSION ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)D. Conguration Select One (1)2.5” = Immersion 2.5“ | 4” = Immersion 4“ | 6” = Immersion 6”E. Immersion Length Select One (1)MODEL #A/Model # Example:TT100B.A/A.IC.4”D.2E.EXPLF.G.EXPL = Hazardous SensorF. Sensor Model No Selection RequiredNote*: Must specify a 3 or 5 Point NIST Certicate with the TTM100 or TTM1K Transmitter aboveNote*: Must specify a 3 or 5 Point NIST Certicate with the TTM100 or TTM1K Transmitter aboveNote*: Must specify a 3 or 5 Point NIST Certicate with the TTM100 or TTM1K Transmitter aboveSpecify Span in ºF or ºC (Best Accuracy in 100ºF Increments)G. Calibrated SpanSpecify Span in ºF or ºC (Best Accuracy in 100ºF Increments)G. Calibrated SpanFront ViewRight ViewTop ViewDIMENSIONAL DRAWING5.38” (136.53mm)5.38” (136.53mm)Available in 2" Probe LengthsAvailable in 2.5", 4” & 6" Probe Lengths & 18" Probe Lengths2.89” (75.34mm)5.31” (134.94mm)3.51” (89.15mm)3.51” (89.15mm)Ø4.05” (102.87mm)Ø4.05” (102.87mm).78” (19.69mm).78” (19.69mm)3.40”(86.42mm)Ø3.75” (95.25mm)Available in 4”, 8", 12"Hazardous RoomHazardous DuctHazardous ImmersionNext >