Automation Components, Inc.GAS | QTS-1710 SERIESGAS | ## Call: 1-888-967-5224 | Web: www.workaci.com QTS-1710 SERIESCombustible Gas TransmitterThe QTS-1710 Series utilizes a standard pellistor bead technology for the measurement of combustible gases. The sensor is resistant to poisoning substances such as Silicones, Sulphur and Chlorinated compounds. The Sensor is mounted to an explosion-proof housing while the transmitter provides a 3-wire, linear 4 to 20 mA output signal that is proportional to the LEL (Lower Explosive Limit) of the calibrated combustible gas. Test jacks are provided to monitor the transmitter signal without having to interrupt the output signal and Zero and Span adjustments allow for eld calibration. Calibration and bump testing should be completed every three months in all combustible or explosive atmospheres. Calibration gases and 0.5 liter/minute gas regulators are not available through ACI. These should be purchased through your local gas supply company or companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®. See the Q8 Combustible and Toxic Gas transmitter product data sheet for all applications that require a local display, remote sensor and a wider range of gases and output options. Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products.Applications: Mechanical Rooms, Warehouses, Refrigeration Plants, Industrial Plants, Process Monitoring, Leak Detection, Parking Garages, Auto/Truck Maintenance FacilitiesThe QTS-1710 Series Gas Transmitters are covered by ACI's Two (2) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.PRODUCT SPECIFICATIONSSupply Voltage | Protection:Supply Current | Power Consumption:Maximum Load (@ 24 VDC):Output Signal:Factory Set Range: Accuracy | Repeatability:Zero Drift:Response Time (T90):Sensor Warm Up TimeSensor Type:Sensor Gas Types:Sensor Life Expectancy:Unit Shelf Life:Replacement Sensor: Recommended Maintenance: Enclosure Specications (Type, Material Type, Flammability, NEMA/IP Rating, Explosion Proof):Operating Temperature:Operating Humidity:Operating Atmospheric Pressure ¹:Recommended Storage Temperature/Humidity:Wiring Connections | Wire Size:Terminal Block Torque Rating:Coverage Area | Mounting Height:Approvals:Product Weight:Product Dimensions (L x W x H):12 to 30 VDC | 0.5A Socketed Pico Fuse125 mA maximum (80 mA, typical) | 3.75 Watts maximum700 Ohms (500 Ohms @ 20 VDC and 200 Ohms @ 12 VDC) 4-20 mA (3-Wire; Power, Gnd/Com, Signal)See Gas Sensor Selection & Specication Table on back of data sheet +/- 1% LEL Methane | +/- 1% LEL Methane< 2% of Range / Month at 68ºF (20ºC)< 30 Seconds, typical (< 10 seconds for 50% Full Scale Step Change)24 Hours (Allow 24 hours before calibrating sensor after initial installation)Dual Element Poison Resistant Catalytic Pellistor BeadHydrocarbon Combustible Gases3 to 5 years, typical 6 Months from date of purchase (Must be installed and operational) Contact ACIAccuracy & Bump test every 3 months or as required by Code (Replace sensor as needed)Industrial Connection Head; Cast Aluminum Epoxy Coated; NEMA 4X (IP66) Weatherproof Rating Type 7 & 9 Explosion Proof Class 1 Div. 1, Groups B, C, D also 316 SS Sensor Housing Group A Rated; CSA, FM (Factory Mutual), EX (Explosion Proof), UL listed-40 to 122ºF (-40 to 50ºC)0 to 99% RH, non-condensing 14.696 psi (1.0132 bar) +/- 10%32 to 68ºF (0 to 20ºC) | 15 to 90% RH, Non-Condensing Screw Terminal Blocks | 16 to 24 AWG (0.51 to 1.30 mm) Shielded Twisted Pair0.37 ft-lb (0.502 Nm) NominalSee Gas Sensor Selection & Specication Table on back of data sheetRoHS, CSA-4828-02 inspected to C22.2 No. 30 and C22.2 No. 142 (CSA File #: 088890 0 000) 5.00 lbs (2.27 kg) Wall Mount Version: 10.70” (271.78 mm) x 5.71” (145.04 mm) x 4.25” (107.95 mm)Duct Mount Version: 7.50” (190.50 mm) x 5.71” (145.04 mm) x 7.50” (190.50 mm)Note: When installed @ > 3000’ above sea level, the gas transmitters must be veried for accuracy & re-calibrated as needed after installationAutomation Components, Inc.GAS | QTS-1710 SERIESDIMENSIONAL DRAWINGFront ViewRight ViewTop ViewGAS | ## Call: 1-888-967-5224 | Web: www.workaci.com Note: Lower Explosive Limit (LEL) | Note**: Low = 1.0’ (0.31m) above oor | Mid = 4.0 to 6.0’ (1.20 to 1.83m) above oor | High = 0.5’ to 1.5’ (0.15 to 0.46m) below ceiling Note*: All transmitters are calibrated using a correlation method with Methane Gas and detection constants as shown. Calibration with actual target gas is available upon special requestSENSOR SELECTION AND SPECIFICATIONCOVERAGE AREA100% LEL In % By Volume2.5 %1.2 %1.3 %3.0 %3.3 %1.3 %1.1 %4.0 %0.79 %2.0 %1.9 %1.0 %1.5 %5.0 %0.85 %2.2 %2.1 %Measurement Range0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LEL0 to 100% LELSquare Footage5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)7500 ft (696.7 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)5000 ft (464.5 m)7500 ft (696.7 m)5000 ft (464.5 m)5000 ft (464.5 m)7500 ft (696.7 m)Radius40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)49 ft (14.9 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)40 ft (12.2 m)49 ft (14.9 m)40 ft (12.2 m)40 ft (12.2 m)49 ft (14.9 m)Mounting HeightMid **Low **Low **Low **Low **Low **Low **High **Low **Low **Low **Low **Low **High **Low **Low **High **Gas TypeAcetyleneBenzeneCyclohexaneEthaneEthanolGasolineHexaneHydrogenIso-OctaneIso-Propyl Alcoholn-Butanen-Octanen-PentaneMethaneNonanen-Propyl AlcoholPropaneSymbolC2H2C6H6C6H12C2H6C2H6O----C6H14H2C8H18C3H8OC4H10C8H18C5H12CH4C9H2OC3H8OC3H80 = Methane 1 = Acetylene4 = n-Butane5 = n-PentaneQTS A. Sensor Series No Selection RequiredC. Conguration Select One (1)S = Aluminum, Epoxy Coated Weatherproof Industrial NEMA 4X, 7, 9 Enclosure1 = Factory ProvidedD. Factory Supplied No Selection RequiredQTS1711XS171 = Combustible Transmitter SeriesB. Gas Transmitter No Selection RequiredX = DefaultE. Revision No Selection RequiredCUSTOM ORDERINGMODEL #Model # Example:SF.XE.1D.0C.171B.QTSA.PG.00H.I.J.0K.0F. Enclosure No Selection RequiredØ1.62”(41.15mm)5.07”(128.78mm)5.71”(145.04mm)4.96”(125.98mm)4.50”(114.30mm)Ø4.25”(107.95mm)Ø.28”(7.08mm)1.35”(34.29mm)Optional Splash Guard Adds 3.10” (78.74mm)7.42” (188.34mm)2 = Ethane3 = Propane6 = n-Octane7 = Hydrogen8 = Gasoline9 = Other (Please Advise)000 = No Protective Sensor Guard | P = Protective Sensor GuardG. Sensor Guard Select One (1)0 = DefaultH. Factory Supplied No Selection Required00 = DefaultI. Factory Supplied No Selection Required0 = DefaultJ. Factory Supplied No Selection Required0 = Default* | X = Non-Standard Calibration (Specify) | S = Special Options (Contact ACI)*K. Calibration/Options Select One (1)ACCESSORIES ORDERINGModel #79030-103Item #126566DescriptionQTS-1710 Combustible Calibration Adaptor-OR-Model # Example:79030-103126566Next >