Platinum RTD | PTC (Positive Temperature Coecient)OneA/100-2W-EXPL and A/1K-2W-EXPL: Two (Non-Polarity Sensitive)A/100-3W-EXPL and A/1K-3W-EXPL: Three (Polarity Sensitive)A/100-xW-EXPL Series: 100 Ohms nominal | A/1K-xW-EXPL Series: 1000 Ohms nominal +/- 0.06% Class A | (Tolerance Formula: +/- ºC = (0.15ºC + (0.002 * |t|)) where |t| is the absolute value of Temperature above or below 0ºC in ºC)-40ºC (-40ºF): +/- 0.23ºC (+/- 0.414ºF) | 0ºC (32ºF): +/- 0.15ºC (+/- 0.27ºF)200ºC (392ºF) = +/- 0.55ºC (+/- 1.00ºF)DIN EN 60751 (IEC 751) | 3850 ppm / ºC+/- 0.03% after 1000 Hours @ 300ºC (572ºF)8 Seconds nominal100 Ohm RTD: 7 mW/ºC (Still Air) | 5 mA1K Ohm RTD: 4 mW/ºC (Still Air) | 3 mA“-D” Enclosure: Feraloy® Iron Alloy, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFG “-I or -INW” Enclosure: Feraloy® Iron Alloy, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFG“-R” Enclosure: Copper-Free Aluminum, -50 to 60ºC (-58 to 140ºF), NEMA 3, 4, 7ABCD, 9EFGCL. I, Div. 1 & 2, Groups A, B, C, DCL. II, Div. 1, Groups E, F, GCL. II, Div. 2, Groups F, GCL. III“-R” Enclosure: UL 1203 | “-D”, “-I” or “-INW” Enclosure: UL 886C22.2 No. 30-40 to 200ºC (-40 to 392ºF)-40 to 85ºC (-40 to 185ºF)10 to 95% RH, non-condensingTwo | 1/2” NPT Female Hubs 0.250” (6.35mm) | ½” NPT (National Pipe Tapered) Thread304 Stainless Steel 304 Stainless Steel | 0.260”½” NPS (National Pipe Straight) Female Thread | ½” NPT (National Pipe Tapered) Male Thread14” (35.6 cm) or 24” (61 cm) | 22 AWG (0.65mm)Etched Teon (PTFE) Colored Leads | Mil Spec 16878/4 Type E)Silver Plated CopperSee table on back of Product Data sheetCE, RoHS2, WEEEAutomation Components, Inc.TEMPERATURE | PLATINUM RTDS | HAZARDOUSPRODUCT SPECIFICATIONSTEMPERATURE | ## Call: 1-888-967-5224 | Web: www.workaci.com DuctImmersionRoomSensor Type | Sensor Curve:Number Sensing Points:Number Wires:Sensor Output @ 0°C (32°F):Sensor Tolerance Class | Accuracy:Din Standard | Temperature Coecient:Sensor Stability:Response Time (63% Step Change):Self-Heating | Maximum Operating Current:Enclosure Specications (Material, Operating Temperature, NEMA Ratings):Enclosure Explosion Proof Rating:Enclosure Dust-Ignition Proof Rating:Enclosure Raintight Rating:Enclosure Wet Locations Rating:Enclosure UL Standards:Enclosure CSA Standards:Sensor Operating Temperature Range:Storage Temperature Range:Operating Humidity Range:Enclosure Hubs | Hub Size:Probe Diameter | Sensor Threads:Probe Material:Thermowell Material | Thermowell Bore Diameter:Thermowell Instrument Thread | Process Thread:Lead Length | Conductor Size:Lead Wire Insulation | Wire Rating:Conductor Material:Product Dimensions | Product Weight:Agency Approvals:HAZARDOUSRoom, Duct & Immersion Platinum RTDThe ACI Hazardous Platinum RTD Series features a ½” NPT Process threaded tting and ¼” diameter stainless steel probe with 22 AWG Etched Teon colored lead wires. The sensors in this series are manufactured using ACI’s proven double encapsulation process to eliminate the eects of moisture upon the sensors and to increase response times using our high quality, thermally conductive epoxy. The Hazardous sensors come standard with a heavy duty Feraloy® Iron or Aluminum Connection Head depending on the conguration ordered. These sensors can be used in Wall Mounted (Room), Duct, and Immersion style congurations and include an O-Ring Seal, Ground Screw, and weather resistant nish. The “INW” Immersion sensor without thermowell can be used with an existing thermowell or paired with any of the Machined thermowells (See Accessories) when higher ow rates, temperatures, pressure rating or corrosion resistance is required. NIST Certicates are also available as shown on the back of the product data sheet. This product should be installed by a trained professional with knowledge of local codes and regulations. Applications: Hazardous Atmospheres, Industrial Sensor Applications, Process control, Exhaust Systems The ACI Hazardous Platinum RTD Series is covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.Front ViewRight ViewTop ViewRevision C0000002 | Rev 1.0Automation Components, Inc.TEMPERATURE | PLATINUM RTDS | HAZARDOUSTEMPERATURE | ## Call: 1-888-967-5224 | Web: www.workaci.com 100 = 100 Ohm Platinum RTD | 1K = 1K Ohm Platinum RTDA/R = RoomHAZARDOUS ROOM ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)2W = Two Wires | 3W = Three WiresC. Number of Wires Select One (1)2W = Two Wires | 3W = Three WiresC. Number of Wires Select One (1)2W = Two Wires | 3W = Three WiresC. Number of Wires Select One (1)D. Conguration No Selection RequiredEXPL = Hazardous SensorE. Sensor Model No Selection RequiredMODEL #A/REXPLEXPLModel # Example:100 = 100 Ohm Platinum RTD | 1K = 1K Ohm Platinum RTDA/D = DuctHAZARDOUS DUCT ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)D. Conguration No Selection Required4” = Duct 4” | 8” = Duct 8” | 12” = Duct 12” | 18” = Duct 18” E. Duct Probe Length Select One (1)---- = No NIST Certicate | NIST = NIST Certicate (Must Specify 1, 3 or 5 Points)G. NIST Select One (1)MODEL #A/DModel # Example:100B.A/A.2WC.DD.4”E.EXPLF.NISTG.---- = No NIST Certicate | NIST = NIST Certicate (Must Specify 1, 3 or 5 Points)F. NIST Select One (1)100B.A/A.2WC.RD.EXPLE.NISTF.EXPL = Hazardous SensorF. Sensor Model No Selection RequiredEXPL100 = 100 Ohm Platinum RTD | 1K = 1K Ohm Platinum RTDA/I = Immersion with Welded Thermowell | INW = Immersion without Welded ThermowellHAZARDOUS IMMERSION ORDERINGA. Sensor Series No Selection RequiredB. Model Series Select One (1)D. Conguration Select One (1)2.5” = Immersion 2.5” | 4” = Immersion 4” | 6” = Immersion 6”E. Immersion Length Select One (1)---- = No NIST Certicate | NIST = NIST Certicate (Must Specify 1, 3 or 5 Points)G. NIST Select One (1)MODEL #A/Model # Example:100B.A/A.3WC.ID.4”E.EXPLF.NISTG.EXPL = Hazardous SensorF. Sensor Model No Selection RequiredDIMENSIONAL DRAWING5.38” (136.53mm)5.38” (136.53mm)Available in 2"Probe LengthsAvailable in 2.5", 4” & 6" Probe Lengths& 18" Probe Lengths2.89” (75.34mm)5.31” (134.94mm)3.51” (89.15mm)3.51” (89.15mm)Ø4.05” (102.87mm)Ø4.05” (102.87mm).78” (19.69mm).78” (19.69mm)3.40” (86.42mm)Ø3.75” (95.25mm)Available in 4", 8", 12” Hazardous RoomHazardous DuctHazardous ImmersionNext >