Automation Components, Inc.GAS | NO2 DUCTGAS | ## Call: 1-888-967-5224 | Web: www.workaci.com NO2 DUCTNitrogen Dioxide Duct SensorThe NO2 Duct Series monitors nitrogen dioxide (NO2) levels and is designed for the continuous monitoring of vehicle exhaust in non-hazardous areas. This series uses a wide spectrum electrochemical sensor to measure the amount of nitrogen dioxide in the environment. It is oered with an operating range of 0 to 6 ppm. The Duct NO2 transmitter is oered in a standard NEMA 1 rated ABS Polycarbonate plastic enclosure. Other options include an LCD display with (2) SPDT Form 1C relays and a buzzer. Calibration gases and a 0.2 to 1 liter/minute ow limiting gas regulator are not available through ACI. These should be purchased through your local gas supply company or on-line companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®. Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products.Applications: Parking Garages, Arenas, Kitchens, Laundry Rooms, Warehouses, Loading Docks, Service Garages, School Bus Parking AreasThe NO2 Room Series is covered by ACI's Two (2) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.PRODUCT SPECIFICATIONSSupply Voltage:Supply Current:Power Usage:Operating Temperature:Operating Humidity:Accuracy:Repeatability:Operating Pressure:Response Time:Sensor Type:Sensor Life:Factory Set Range:Indicators:Outputs:Relay & Buzzer (Optional):Relay Life Expectancy:Time Delays:Storage:Unit Shelf Life:Duct Kit Tubing Material:Duct Kit Tubing Length:Duct Kit In-Line Filter:Duct Kit Pitot Tube:Enclosure:Terminal Blocks:Terminal Block Torque Rating:Communication Wiring:Equipment Needed For Calibration:Replacement NO2 Sensor:Product Dimensions:Product Weights:24 VAC +/- 10% Floating; 24 VAC +/- 10%, One side Grounded; 24 VDC100 mA nominal | 250 mA maximum 6.6 Watts maximum -4ºF to 104ºF (-20ºC to 40ºC)15 to 90% RH Continuous, non-condensing; 0 to 99% RH Intermittent, non-condensing+/- 2.5% of Reading+/- 1% of ReadingAtmospheric +/- 10%Less than 60 Seconds for 90% of step changeElectrochemical2-3 years under Normal Conditions0 to 6 ppm | 0 to 10 ppm Field AdjustableAlphanumeric, 2 line X 8 digit LCD / (2) Red LED’s for Relay StatusAnalog 4-20 mA or 2-10V Jumper Selectable; Digital RS-485Two SPDT Form C, Dry Contact, 1A @ 30 VDC/0.5A @ 125 VAC (Resistive Load), Buzzer Rating 85 dB @ one foot200,000 cycles minimum with 1A @ 30 VDCActuation / De-Actuation: 0 to 60 Minutes in 5 minute Increments32ºF to 68ºF6 months from date of purchaseVinyl18“5 micron3 5/32”, Polycarbonate/ABS Blend / UL94VPolycarbonate/ABS Blend, Fire RetardantPower wiring: 16 to 26 AWG (0.2 to 1.00 nm²) Shielded Twisted Pair0.37 ft-lbs (0.5n-3m) NominalBeldon 9841 or equal0.5 lpm Regulator, zero & span gas (supplied by local vendor) Calibration adapter (Part # 83830-020-000)Part# 6300-0035(H) 6.00” (152.4 mm) x (W) 3.5“ (88.9 mm) x (D) 1.6” (40.6 mm)1.00 lbs (0.45 kg)Note: Sensors and system should be scheduled to be tested for accuracy and functionality every 6 months for toxic, and every 3 months for combustible | Recalibrate or replace sensor boards if necessaryAutomation Components, Inc.GAS | NO2 DUCTGAS | ## Call: 1-888-967-5224 | Web: www.workaci.com 0.51”(12.95mm)0.41” (10.41mm)0.16”(4.06mm)5.15” (130.81mm)Ø.35”(8.89mm)1.08”(27.69mm)36.00”(914.40mm)0.50”(12.70mm)DIMENSIONAL DRAWINGFront, Side ViewsTop View3.50”(88.90mm)6.00”(152.40mm)1.20”(30.48mm)0.41”(10.41mm)0.41”(10.41mm)Filter Ø.21”(5.33mm)STANDARD ORDERINGModel #NO2-DNO2-D-RB-DItem #109680113012DescriptionNO2 Duct Mount, Standard EnclosureNO2 Duct Mount with Display, Relays (2 x SPDT), Buzzer, Standard Enclosure-OR-Model # Example:113012NO2-D-RB-DACCESSORIES ORDERINGModel #6300-003583830-020-000Item #128873127649DescriptionNO2 Replacement SensorCalibration Adapter-OR-Model # Example:1288736300-0035Next >