Toxic Sensor SeriesThe CTS-M5 Series has a microprocessor based transmitter. It uses an Electrochemical gas sensor to monitor a variety of gases. The CTS-M5 Series offers great value since it includes many standard features that can only be found as expensive options in other manufacturer’s models. A digital display (LCD), push-button programming and on-board meter jacks are all standard. The transmitter provides an analog output of 4-20 mA or 2-10 VDC, proportional to the measured gas range, for transmission to the building management system. The CTS-M5 Series offers flexibility and simplicity in one package. The relay setpoints may be seen as increasing or decreasing actuation simply by adjusting the deadband relationship. Set the deactuation point above the actuation setpoint and the CTS-M5 will automatically alarm on decreasing concentrations. Plus, calibration is extremely simple. First, apply the calibration gas and then adjust the potentiometer to the desired reading on the display.The CTS-M5 Series are covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI's Sensors & Transmitters catalog or can be found on ACI's web site, which is: www.workaci.com. CTS-M5Automation Components, Inc.Automation Components, Inc.CTS-M5GASORDERINGSPECIFICATIONSSelect one Gas Type (A), one Enclosure (B), one Relay (C), & one Conformal Coating Option (D). NOTE: The LCD option is not available for NEMA 4X related configurations. Gas Type Enclosure130 (Oxygen)190 (Nitric Oxide)220 (Ammonia)Q0 (NEMA 1 Wall Mount)D0 (Duct Mount)N0 (NEMA 4X)X000CTS-M5After completing (A), (B), (C) & (D) from the above table, fill in the Part Number Table below. “Sensor Series” (CTS-M5), “Revision” (X) & “Factory Provided” (000) are factory defaults. An example part number is offered. EXAMPLE: CTS-M5130X - Q0RW000BUILD PART NUMBER REVISIONSENSOR SERIESFACTORY PROVIDED Relays0 (None) (Standard)R (2) SPDT Form 1C Relays, LCD & Buzzer) Conformal Coating0 (No Coating) (Standard)W (Conformal Coating)Automation Components, Inc.1-888-967-5224 www.workaci.com GASCTS-M5Supply VoltageSupply CurrentSensor TypeSensor Life SpanGas Measurement RangeOutputsAccuracy/RepeatabilityRelay RatingTime DelaysBuzzer RatingResponse TimeIndicatorsOperating Temperature RangeOperating Humidity RangeOperating Pressure RangeMaximum Sensor Coverage AreaMounting Height Above Floor+24 VDC or 24 VAC floating or one side ground100 mA nominal/250 mA maximumElectrochemical2 to 3 years typical (under normal conditions)O2, 0 to 25% v/v | NO, 0 to 100 ppm | NH3, 0 to 50 ppm4-20 mA, +2-10 VDC, Digital RS-485, (2) SPDT Form 1C Relay+/- 2.5% of Reading/+/- 1.0% of Reading(2) SPDT Form 1C rated @1 Amp dry contactActuation: 0-60 minutes in 5 minute increments, De-Actuation: 0-60 minutes in 5 minute incrementsRated for 85 dB @ one footLess than 60 seconds typical for a 90% step changeTwo line 8 digit Alpha Numberic LCD (2) Red LED’s for Relay Status -4° to 104°F (-20 to 40°C) 15 to 90%, non-condensing, 0 to 99% Intermittent (non-condensing)Atmospheric +/- 10%7,500 ft2 (O2, NH3): 5,000 ft2 (NO, NO2)4 to 6’ (NO, O2): 0.5 to 1.5’ (NH3) Next >